As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.

NPort S9650I Series

8/16-port rugged device server with managed Ethernet switch

moxa-nport-s9650i-series-image-(1).jpg | Moxa
moxa-nport-s9650i-series-image-1-(1).jpg | Moxa
moxa-nport-s9650i-series-image-2-(1).jpg | Moxa
moxa-nport-s9650i-series-image-3-(1).jpg | Moxa
moxa-nport-s9650i-series-image-4-(1).jpg | Moxa
moxa-nport-s9650i-series-image-5-(1).jpg | Moxa
moxa-nport-s9650i-series-image-6-(1).jpg | Moxa

Features and Benefits

  • Supports up to 4 managed Ethernet switch ports (fiber available with some optional network modules)
  • 8/16-port RS-232/422/485 serial interface
  • Supports DNP3 and Modbus protocols
  • Ethernet redundancy with Turbo Ring/Chain and RSTP/STP supported
  • Real COM/TTY drivers for Windows and Linux
  • IEC 61850-3, IEEE 1613 (power substations) compliant
  • IEEE 1588v2 and IRIG-B time synchronization functions
  • Supports IEC 61850 MMS protocol
  • Security features based on IEC 62443/NERC CIP
  • -40 to 85°C wide operating temperature

Certifications

  • moxa-iec61850-3-ieee1613-black-certification-logo-image.png | Moxa
  • moxa-ul-listed-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The NPort S9650I Series 8/16-port RS-232/422/485 device servers, which come with a built-in full-function managed Ethernet switch, are designed specifically for the harsh environmental conditions found in electrical substations. With both fiber and wired Ethernet ports supported, the combination of a device server and Ethernet switch gives users the ability to easily install, manage, and maintain the NPort S9650I itself, as well as attached serial devices.

Electromagnetic Compatibility for Harsh Substation Environments

The NPort S9650I Series supports a high level of surge protection to prevent damage from the types of power surges and EMI one finds in electrical substations and industrial automation applications. Combined with a -40 to 85°C operating temperature range and galvanized steel housing, the NPort S9650I is suitable for a wide range of industrial environments.

Another plus is the NPort S9650I’s dual power supplies, which provide both redundancy, as well as a wide range of voltage inputs. The WV models accept a 24/48 VDC power input (ranging from 18 to 72 VDC), and the HV models accept a power input of 88 to 300 VDC and 85 to 264 VAC.

Power SCADA With IEC 61850 MMS for Easy Maintenance

The current trend in power SCADA applications is to control and monitor both IT devices (switches, routers, etc.) and IEDs (sensors, actuators, etc.) with the MMS protocol. Contrast this with the more traditional management approach of using SNMP for IT devices and MMS for IEDs. In fact, SIs may even need to manage a variety of legacy devices that use proprietary communications protocols.

The NPort S9650I device servers are the world’s first device servers to integrate MMS into an IT-type device designed specifically for power SCADA applications. The NPort S9650I even supports using MMS to monitor serial communications between the S9650I and legacy devices.

Supports Modbus/DNP3 Protocol Gateway

The NPort S9650I Series provides maximum flexibility for integrating industrial Modbus/DNP3 networks of all types and sizes. The NPort S9650I is designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master/slave combination, including simultaneous serial and Ethernet masters.

The NPort S9650I device servers also support protocol conversion between DNP3 serial and DNP3 IP, and all models are ruggedly constructed to ensure reliable operation.

Cybersecurity Features Based on IEC 62443/NERC CIP

The NPort S9650I Series has security features based on IEC 62443/NERC CIP to provide a high level of cybersecurity. Protecting mission-critical networks from cyberattacks is a high priority for industrial automation applications, which can suffer large losses due to extended network downtime.

Supports IEEE 1588v2 and IRIG-B Time Synchronization Functions

The NPort S9650I Series, which has a modular design that supports IEEE 1588v2 and IRIG-B time synchronization, is able to interconnect and synchronize multiple types of intelligent electronic devices (IEDs) that use different communication protocols. The time source is provided via IEEE 1588v2 and converted to IRIG-B for distribution to the IEDs via the serial ports or via a dedicated IRIG-B BNC connector.

Ring Redundancy at the Device Level

Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration to support the most demanding control applications. The NPort S9650I Series integrates a full-function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S9650I Series can achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

  • Alarm Contact Channels

    Resistive load: 1 A @ 24 VDC

  • 10/100BaseT(X) Ports (RJ45 connector)

    NPort S9650I-E Series: 4 RJ45 ports
    NPort S9650I-MSC Series: 2 RJ45 ports
    NPort S9650I-SSC Series: 2 RJ45 ports
    NPort S9650I-IRIG Series: 2 RJ45 ports

  • 100BaseFX Ports (multi-mode SC connector)

    NPort S9650I-MSC Series: 2 multi-mode SC ports

  • 100BaseFX Ports (single-mode SC connector)

    NPort S9650I-SSC Series: 2 single-mode SC ports

  • Magnetic Isolation Protection

    1.5 kV (built-in)

  • Optical Fiber

  • Standards

    IEEE 802.1D-2004 for Spanning Tree Protocol
    IEEE 802.1p for Class of Service
    IEEE 802.1Q for VLAN Tagging
    IEEE 802.1w for Rapid Spanning Tree Protocol
    IEEE 802.1X for authentication
    IEEE 802.3 for 10BaseT
    IEEE 802.3ad for Port Trunk with LACP
    IEEE 802.3u for 100BaseT(X) and 100BaseFX

  • IGMP Groups

    256

  • Max. No. of VLANs

    64

  • Priority Queues

    4

  • VLAN ID Range

    VID 1 to 4094

  • Configuration Options

    Web Console (HTTP/HTTPS), Windows Utility, Device Search Utility (DSU), MCC Tool, Command Line Interface (CLI) through Serial/Telnet/SSH

  • Management

    DHCP Client, DHCP Option 82, HTTP, IEC 61850 MMS, IPv4, LLDP, Port Mirror, RARP, RMON, SMTP, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Web Console

  • Filter

    GMRP, GVRP, IGMP v1/v2

  • Windows Real COM Drivers

    Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded

  • Linux Real TTY Drivers

    Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x

  • Fixed TTY Drivers

    SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X

  • Android API

    Android 3.1.x and later

  • Industrial Protocols

    Modbus TCP Server (Slave), DNP3 TCP Outstation

  • Time Management

    NTP Server/Client, SNTP, IEEE 1588v2 PTP (hardware-based), IRIG-B

  • MIB

    Bridge MIB, Device Settings MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RFC1213, RFC1317, RMON MIB Groups 1, 2, 3, 9, RSTP MIB

  • Redundancy Protocols

    RSTP, Turbo Chain, Turbo Ring v1, Turbo Ring v2

  • Security

    HTTPS/SSL, Local Account Accessibility, TACACS+, RADIUS, SSH

  • PWM/PPS Output, BNC Connector

    NPort S9650I-IRIG Series: 1

  • PWM/PPS Output, DB9 Female

    NPort S9650I-8B-2HV-IRIG-T: 8
    NPort S9650I-16B-2HV-IRIG-T: 16

  • PWM Input, BNC Connector

    NPort S9650I-IRIG Series: 1

  • Connector

    NPort S9650I-8/-16 Series: DB9 male
    NPort S9650I-8B/-16B Series: DB9 female
    NPort S9650I-8F/-16F Series: Multi-mode fiber ST connector

  • No. of Ports

    8 or 16

  • Serial Standards

    RS-232, RS-422, RS-485

  • Operation Modes

    Real COM mode, RFC2217 mode, TCP Client mode, TCP Server mode, UDP mode, Modbus mode, DNP3 mode, DNP3 Raw Socket mode, Disabled

  • Baudrate

    50 bps to 921.6 kbps (supports non-standard baudrates)

  • Data Bits

    5, 6, 7, 8

  • Stop Bits

    1, 1.5, 2

  • Parity

    None, Even, Odd, Space, Mark

  • Flow Control

    None, RTS/CTS, XON/XOFF

  • Isolation

    2 kV

  • Surge

    4 kV

  • RS-485 Data Direction Control

    ADDC® (automatic data direction control)

  • Pull High/Low Resistor for RS-485

    1 kilo-ohm, 150 kilo-ohms

  • Terminator for RS-485

    120 ohms

  • Console Port

    RS-232 (TxD, RxD, GND), 10-pin RJ45 (19200, n, 8, 1)

  • RS-232

    NPort S9650I-IRIG Series: TxD, RxD, RTS, CTS, DTR/+IRIG-B, DSR, DCD, GND
    NPort S9650I Series: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

  • RS-422

    NPort S9650I-IRIG Series: TxD+, TxD-, RxD+, RxD-, GND, +IRIG-B
    NPort S9650I Series: Tx+, Tx-, Rx+, Rx-

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    NPort S9650I-IRIG Series: Data+, Data-, GND, +IRIG-B
    NPort S9650I Series: Data+, Data-, GND

  • Ethernet Interface

    Turbo Ring, Master, Coupler, Reserved

  • Max. No. of Client Connections

    32

  • Max. No. of Server Connections

    16

  • Max. No. of Master Connections

    16

  • Max. No. of Outstation Connections

    32

  • Automatic Reboot Trigger

    Built-in WDT

  • Alert Tools

    Built-in buzzer and RTC (real-time clock)

  • No. of Power Inputs

    2

  • Reverse Polarity Protection

    Supported

  • Input Current

    0.65 A @ 100 VAC, 0.47A @ 100 VDC

  • Input Voltage

    110/220 VAC/VDC (100 to 240 VAC, 100 to 250 VDC)

  • Housing

    Metal

  • Installation

    19-inch rack mounting

  • Dimensions

    457 x 32 x 330 mm (18 x 1.25 x 12.99 in)

  • Weight

    Product only: 5.15 kg (11.35 lb)

  • Operating Temperature

    -40 to 85°C (-40 to 185°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • EMC

    EN 61000-6-2/-6-4

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
    IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
    IEC 61000-4-8 PFMF
    IEC 61000-4-11

  • Environmental Testing

    IEC 60068-2-2
    IEC 60068-2-14

  • Power Substation

    IEC 61850-3, IEEE 1613

  • Safety

    EN 61010-2-201, UL 61010-2-201

  • Shock

    IEC 60068-2-27

  • Vibration

    IEC 60068-2-6, IEC 60068-2-64

  • Green Product

    RoHS, CRoHS, WEEE

  • Time

    NPort S9650I-8-2HV-E-T: 224,670 hrs
    NPort S9650I-8-2HV-MSC-T: 220,944 hrs
    NPort S9650I-8-2HV-SSC-T: 220,944 hrs
    NPort S9650I-8B-2HV-IRIG-T: 213,025 hrs
    NPort S9650I-8F-2HV-E-T: 311,734 hrs
    NPort S9650I-8F-2HV-MSC-T: 304,587 hrs
    NPort S9650I-8F-2HV-SSC-T: 304,587 hrs
    NPort S9650I-16-2HV-E-T: 158,816 hrs
    NPort S9650I-16-2HV-MSC-T: 156,949 hrs
    NPort S9650I-16-2HV-SSC-T: 156,949 hrs
    NPort S9650I-16B-2HV-IRIG-T: 157,770 hrs
    NPort S9650I-16F-2HV-E-T: 261,817 hrs
    NPort S9650I-16F-2HV-MSC-T: 256,761 hrs
    NPort S9650I-16F-2HV-SSC-T: 256,761 hrs

  • Standards

    Telcordia SR332

Software, Firmware, and Drivers

FILTER

Name Type Checksum Version Operating System Release Date
Real TTY Linux driver v5.3 (kernel 5.x)
113.3 KB
Driver
SHA-512
v5.3
  • Linux Kernel 5.x
Oct 18, 2023 Oct 18, 2023 Release notes
MXconfig Plugin
3.3 MB
Software Package
SHA-512
v1.4
  • Windows 10
  • Windows 7
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
Jul 17, 2023 Jul 17, 2023 Release notes
Device Search Utility
2.2 MB
Utility
SHA-512
v2.7
  • Windows 10
  • Windows 11
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows 95
  • Windows 98
  • Windows 98 SE
  • Windows NT
  • Windows Server 2003
  • Windows Server 2008
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022
  • Windows Vista
  • Windows XP
Jun 28, 2023 Jun 28, 2023 Release notes
MXview plugin
32.8 MB
Software Package
SHA-512
v1.4
  • Windows 10
  • Windows 7
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
May 02, 2023 May 02, 2023 Release notes
Real TTY Linux drivers v4.2 (kernel 4.x)
114.9 KB
Driver
SHA-512
v4.2
  • Linux Kernel 4.x
Jan 17, 2023 Jan 17, 2023 Release notes
Device Server Android API
18.0 MB
Library
SHA-512
v1.1
  • Android
Dec 22, 2022 Dec 22, 2022 Release notes
MIB file for NPort S9650I Series
243.8 KB
Software Package
SHA-512
v1.1
Nov 01, 2021 Nov 01, 2021 Release notes
Firmware for NPort S9650I Series
2.9 MB
Firmware
SHA-512
v1.1
Nov 01, 2021 Nov 01, 2021 Release notes
Real TTY drivers for Linux 2.x.x
92.2 KB
Driver
SHA-512
v2.0
  • Linux Kernel 2.4.x
  • Linux Kernel 2.6.x
Oct 24, 2019 Oct 24, 2019 Release notes
Real TTY drivers for Linux 3.x.x
95.0 KB
Driver
SHA-512
v3.0
  • Linux Kernel 3.x
Oct 24, 2019 Oct 24, 2019 Release notes
Windows Driver Manager (Windows Vista, Server 2008, and prior)
2.6 MB
Driver
SHA-512
v2.0
  • Windows 2000
  • Windows 95
  • Windows 98
  • Windows 98 SE
  • Windows ME
  • Windows NT
  • Windows Server 2003
  • Windows Server 2008
  • Windows Vista
  • Windows XP
Aug 01, 2019 Aug 01, 2019 Release notes
Windows Driver Manager (for Windows 7, Server 2008, or later)
2.9 MB
Driver
SHA-512
v3.1
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
May 20, 2019 May 20, 2019 Release notes
Software Package for NPort S9650I Series (MMS ICD file)
20.5 KB
Software Package
SHA-512
v1.0
Jan 18, 2019 Jan 18, 2019 Release notes
Driver for NPort S9650I Series (Windows CE)
230.5 KB
Driver
SHA-512
v1.6
  • Windows CE 5.0
  • Windows CE 6.0
Nov 20, 2018 Nov 20, 2018 Release notes
Driver for NPort S9650I Series (UNIX)
73.0 KB
Driver
SHA-512
v3.5
  • FreeBSD 5.x
  • FreeBSD 6.x
  • FreeBSD 7.x
  • FreeBSD 8.x
  • HP-UX
  • IBM AIX 5.3
  • Mac OS X
  • QNX 4.x
  • QNX 6.x
  • SCO OpenServer 5
  • SCO OpenServer 6
  • SCO UnixWare 7
  • Solaris 10
Nov 19, 2018 Nov 19, 2018 Release notes
Driver for NPort S9650I Series (Windows XP Embedded)
1.2 MB
Driver
SHA-512
v1.14
  • Windows XP Embedded
Nov 19, 2018 Nov 19, 2018 Release notes
PComm Lite - Serial Communication Tool for Windows
1.6 MB
Utility
SHA-512
v1.6
  • Windows 2000
  • Windows 7
  • Windows Server 2003
  • Windows Server 2008
  • Windows Server 2008 R2
  • Windows Vista
  • Windows XP
May 14, 2012 May 14, 2012 Release notes

Support Documents

Name Type Version Release Date
Moxa CLI Configuration Tool User Manual
1.0 MB
Manual v2.2 Jan 26, 2024 Jan 26, 2024
Tech Note: Real COM mode for NPort
479.5 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: TCP Server Mode for NPort
395.0 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: TCP Client Mode for NPort
394.5 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Moxa Real TTY Driver Porting Guide for Arm-based Platforms
372.3 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: UDP Mode for NPort
397.2 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Ethernet Modem Mode
429.4 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Pair Connection Mode
544.0 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Reverse Telnet Mode for NPort
364.5 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Fixed TTY Driver for NPort
389.7 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Accessing Multiple NPorts Behind NAT
497.2 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Real TTY Driver for NPort
379.2 KB
Tech Note v2.0 Jun 08, 2023 Jun 08, 2023
Tech Note: Moxa Real TTY Driver Porting Guide for Arm-based Platforms
371.7 KB
Tech Note v1.0 Aug 05, 2021 Aug 05, 2021
QIG for NPort S9000 Series
742.2 KB
QIG v3.1 May 19, 2021 May 19, 2021
Datasheet for NPort S9650I Series
963.9 KB
Datasheet v1.2 Dec 16, 2019 Dec 16, 2019
Manual for NPort S9650I Series
11.9 MB
Manual v3.0 Oct 29, 2019 Oct 29, 2019
2D CAD for NPort S9650I Series (2D_NPort S9650I-16-2HV-E-T/2D_NPort S9650I-16-2HV-MSC-T/2D_NPort S9650I-16-2HV-SSC-T/2D_Nport-S9650_ST_RJ/2D_Nport-S9650-DB9-BNC)
1.3 MB
2D CAD Jun 05, 2019 Jun 05, 2019
Tech Note: Increasing Manageability of Your Network Equipment-Including Your Legacy IEDs
892.2 KB
Tech Note v1.0 Jan 03, 2019 Jan 03, 2019
2D CAD for NPort S9650I Series (ST-RJ)
228.5 KB
2D CAD Dec 07, 2018 Dec 07, 2018
2D CAD for NPort S9650I Series (DB9-BNC)
232.9 KB
2D CAD Dec 07, 2018 Dec 07, 2018
Moxa CLI Configuration Tool User's Manual
1.1 MB
Manual v2.0 Dec 06, 2018 Dec 06, 2018
Tech Note: TCP Server Mode for NPort
311.3 KB
Tech Note v1.0 Jun 30, 2013 Jun 30, 2013
Tech Note: Real COM Mode for NPort
253.0 KB
Tech Note v1.0 Nov 04, 2009 Nov 04, 2009
Tech Note: TCP Client Mode for NPort
224.4 KB
Tech Note v1.0 Nov 04, 2009 Nov 04, 2009
Tech Note: Accessing Multiple NPorts Behind NAT
482.6 KB
Tech Note v1.0 Nov 04, 2009 Nov 04, 2009
Tech Note: UDP Mode for NPort
173.2 KB
Tech Note v1.0 Nov 04, 2009 Nov 04, 2009
Tech Note: Fixed TTY Driver for NPort
207.6 KB
Tech Note v1.0 May 22, 2009 May 22, 2009
Tech Note: Real TTY Driver for NPort
204.2 KB
Tech Note v1.0 May 22, 2009 May 22, 2009

Available Models (14)

Show Images
moxa-nport-s9650i-8-2hv-e-t-image.jpg | MoxaNPort S9650I-8-2HV-E-Tmoxa-nport-s9650i-8-2hv-msc-t-image.jpg | MoxaNPort S9650I-8-2HV-MSC-Tmoxa-nport-s9650i-8-2hv-ssc-t-image.jpg | MoxaNPort S9650I-8-2HV-SSC-Tmoxa-nport-s9650i-8b-2hv-irig-t-image.jpg | MoxaNPort S9650I-8B-2HV-IRIG-T
No. of Serial Ports8888
Serial Port ConnectorDB9 maleDB9 maleDB9 maleDB9 female
IRIG-B Time Sync
No. of Ethernet Ports4442
Ethernet Port Connector4 x RJ452 x RJ45, 2 x multi-mode SC fiber2 x RJ45, 2 x single-mode SC fiber2 x RJ45
Add to QuoteView BagAdd to QuoteView BagAdd to QuoteView BagAdd to QuoteView Bag
moxa-nport-s9650i-8f-2hv-e-t-image.jpg | MoxaNPort S9650I-8F-2HV-E-Tmoxa-nport-s9650i-8f-2hv-msc-t-image.jpg | MoxaNPort S9650I-8F-2HV-MSC-Tmoxa-nport-s9650i-8f-2hv-ssc-t-image.jpg | MoxaNPort S9650I-8F-2HV-SSC-Tmoxa-nport-s9650i-16-2hv-e-t-image.jpg | MoxaNPort S9650I-16-2HV-E-T
No. of Serial Ports88816
Serial Port ConnectorMulti-mode ST fiberMulti-mode ST fiberMulti-mode ST fiberDB9 male
IRIG-B Time Sync
No. of Ethernet Ports4444
Ethernet Port Connector4 x RJ452 x RJ45, 2 x multi-mode SC fiber2 x RJ45, 2 x single-mode SC fiber4 x RJ45
Add to QuoteView BagAdd to QuoteView BagAdd to QuoteView BagAdd to QuoteView Bag
moxa-nport-s9650i-16-2hv-msc-t-image.jpg | MoxaNPort S9650I-16-2HV-MSC-Tmoxa-nport-s9650i-16-2hv-ssc-t-image.jpg | MoxaNPort S9650I-16-2HV-SSC-Tmoxa-nport-s9650i-16b-2hv-irig-t-image.jpg | MoxaNPort S9650I-16B-2HV-IRIG-Tmoxa-nport-s9650i-16f-2hv-e-t-image.jpg | MoxaNPort S9650I-16F-2HV-E-T
No. of Serial Ports16161616
Serial Port ConnectorDB9 maleDB9 maleDB9 femaleMulti-mode ST fiber
IRIG-B Time Sync
No. of Ethernet Ports4424
Ethernet Port Connector2 x RJ45, 2 x multi-mode SC fiber2 x RJ45, 2 x single-mode SC fiber2 x RJ454 x RJ45
Add to QuoteView BagAdd to QuoteView BagAdd to QuoteView BagAdd to QuoteView Bag
moxa-nport-s9650i-16f-2hv-msc-t-image.jpg | MoxaNPort S9650I-16F-2HV-MSC-Tmoxa-nport-s9650i-16f-2hv-ssc-t-image.jpg | MoxaNPort S9650I-16F-2HV-SSC-T
No. of Serial Ports1616
Serial Port ConnectorMulti-mode ST fiberMulti-mode ST fiber
IRIG-B Time Sync
No. of Ethernet Ports44
Ethernet Port Connector2 x RJ45, 2 x multi-mode SC fiber2 x RJ45, 2 x single-mode SC fiber
Add to QuoteView BagAdd to QuoteView Bag

Field-to-SCADA Interoperability for Legacy Substation Retrofit

Via the Industry’s First IEC 61850 MMS Device Server

LEARN MORE

product image

Buy online from distributors

Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback