As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.
MOXA

Modbus TCP Gateways

Whether single or multiple serial ports, Moxa’s Modbus TCP gateway solutions convert data in networks between Modbus RTU/ASCII, Modbus TCP, DNP3, CANopen, J1939, PROFIBUS, BACnet/IP, IEC 101/104, and IEC 61850, making configuration, troubleshooting, and conversion quick and easy.

MGate MB3480
MGate MB3180/MB3280/MB3480 Series

4-port standard Modbus gateway

Ethernet Interface
  • 10/100BaseT(X) Ports (RJ45 connector)

    • Auto MDI/MDI-X connection
  • Magnetic Isolation Protection

    • 1.5 kV (built-in)
Ethernet Software Features
  • Industrial Protocols

    • Modbus TCP Client (Master)
      Modbus TCP Server (Slave)
  • Configuration Options

    • Web Console (HTTP/HTTPS)
      Device Search Utility (DSU)
      MGate Manager
      MCC Tool
      Telnet Console
  • Management

    • ARP
      DHCP Client
      DNS
      HTTP
      HTTPS
      SNMPv1/v2c/v3 Trap
      TCP/IP
      Telnet
      UDP
      SMTP
      SNMP Trap
      NTP Client
  • MIB

    • RFC1213, RFC1317
  • Time Management

    • NTP Client
Security Functions
  • Authentication

    • Local database
  • Encryption

    • HTTPS
      AES-128
      AES-256
      SHA-256
  • Security Protocols

    • HTTPS (TLS 1.2)
Serial Interface
  • No. of Ports

    • 4
  • Connector

    • DB9 male
  • Serial Standards

    • RS-232/422/485 (software-selectable)
  • Baudrate

    • 50 bps to 921.6 kbps
  • Data Bits

    • 7, 8
  • Parity

    • None
      Even
      Odd
      Space
      Mark
  • Stop Bits

    • 1, 2
  • Flow Control

    • DTR/DSR
      RTS Toggle (RS-232 only)
      RTS/CTS
  • RS-485 Data Direction Control

    • ADDC (automatic data direction control)
  • Pull High/Low Resistor for RS-485

    • 1 kilo-ohm, 150 kilo-ohms
  • Terminator for RS-485

    • 120 ohms
Serial Signals
  • RS-232

    • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
  • RS-422

    • Tx+, Tx-, Rx+, Rx-, GND
  • RS-485-2w

    • Data+, Data-, GND
  • RS-485-4w

    • Tx+, Tx-, Rx+, Rx-, GND
Serial Software Features
  • Industrial Protocols

    • Modbus RTU/ASCII Master
      Modbus RTU/ASCII Slave
Modbus (Transparent)
  • Max. No. of Client Connections

    • 16
  • Max. No. of Server Connections

    • 32
Power Parameters
  • Input Voltage

    • 12 to 48 VDC
  • Input Current

    • 365 mA @ 12 VDC
  • Power Connector

    • Power jack and terminal block
Physical Characteristics
  • Housing

    • Metal
  • IP Rating

    • IP30 For the MGate MB3480, the two screws provided with the wall-mounting kit must be used to fasten the kit to the bottom of the MGate, and the MGate must be properly attached to the terminal block for power input.
  • Dimensions (with ears)

    • 35.5 x 102.7 x 181.3 mm (1.40 x 4.04 x 7.14 in)
  • Dimensions (without ears)

    • 35.5 x 102.7 x 157.2 mm (1.40 x 4.04 x 6.19 in)
  • Weight

    • 740 g (1.63 lb)
Environmental Limits
  • Operating Temperature

    • 0 to 55°C (32 to 131°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
Standards and Certifications
  • EMC

    • EN 55032/35
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
      IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
      IEC 61000-4-5 Surge: Power: 1 kV; Signal: 2 kV
      IEC 61000-4-6 CS: 3 V
      IEC 61000-4-8 PFMF
      IEC 61000-4-11
  • Safety

    • IEC 62368-1
      UL 62368-1
      IEC 60950-1
MTBF
  • Time

    • 1,213,993 hrs
  • Standards

    • Telcordia SR332
Warranty
Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback